At Protech, we believe that while experience enriches the approach of design excellence, the foundation of the design lies on the compliance, review and adopting the applicable Codes and Guidelines.


KEY HIGHLIGHTS IN PRESENT ASSIGNMENT
-Tallest building in National Capital Region +300 meters (under design partially executed)
-24 MW of power Distribution in one project
-10,000 TR Air conditioning through centralized chilled water and VRF system.
-1800 KLD of water distribution and sewage treatment in One project
-Achieved +500 sq.ft/TR Air Conditioning for Business Occupancy.
-Benchmarking EPI 80 kWh/sq.Meter/Year.
-Planned HT Generator (11kV) with stand by Transformer complete with 11kV RMU
All above in compliance to NBC,MoEF, LEED,
AHJ requirements.

At Protech, our working, ideas & commitment has led to improvisation in Codes & Standards.
With over 40 Years of combined Senior Management Experience in MEP Services and having participated in Design and Senior Leadership Role in the MEP Design Services of Healthcare Projects, Hotels, Retail, Commercial, Offices, Mixed Use, Plotted Development and Tall Buildings, we are committed to bring Excellence in our Projects towards Fire Engineering Design.
​
• Protech Team is part of Technical Committee at National Building Code of India and worked closely in the revision of 2005 Code.
​
• Protech Team is Visiting faculty at School of Planning and Architecture with over 15 Years of Teaching Contribution.
​
• Protech has active Membership in the following Associations with leading contribution in design enrichment and enhancement.

At Protech, we believe that while experience enriches the approach of design excellence, the foundation of the design lies on the compliance, review and adopting the applicable Codes and Guidelines.
Following Codes & Standards are basis of our Design and Review:
​
Fire & Life Safety :: NBC Part 4, NFPA, HM Guidelines UK, CIBSE, IFC, IBC.
Fire Alarm & Building Management/ Controls :: NFPA 72, EN Standards, ASHRAE, CIBSE, UL864.
​
HVAC :: NBC Part 8 Section 3, ASHRAE, CIBSE.
​
Electrical :: NBC Part 8 Secion3, National Electric Code, Indian Electricity Rules, The Electricity Act, NFPA 70.
​
Provide advice on all planning regulation & associated code inputs, to ensure the client is able to maximize the commercial opportunity within the realms of the regulations.

Design Offerings
Design & Review of:
​
Fire compartmentation and separations aspect (horizontally and vertically compartmentation between floors) including Fire Barrier/ Fire shutter “Go/ No Go” requirements/ allowances.
Means of Egress with clarity on Exit Access, Exit and Exit Discharge. Calculation and provision of fire stair core numbers, sizes, locations, corridors.
Underground / basement aspects relating to car parking and retail levels.
Overground Life Safety aspects relative to Retail, F&B, Offices with relationship on occupancy calculations and exits. Associated heights and location being also the reference requirement.
​
Firefighting access - Fire Tender routes (in consultation to AHJ) and associated conditions (potentially impacting on traffic and servicing routes.
Structural and Material Fire Rating including surface flame spread.
Façade Fire issues and mitigation.
Smoke mitigation system as per NFPA and CIBSE and also local compliance's requirements.
Fire Alarm Cause and Effect Matrix and Integration.
MEP Services – Fire Detection, Fire Protection & Fighting.
A few facts about Protech Consulting.

Electrical Fire Safety | Leaders in Fire & Electrical Safety Audits | Protech
Electrical Fire Safety which includes Fire Audit & Electrical Audit help organisations to identify & control Electrical Fire Safety Hazards which are increasingly posing higher risks to people and property in industries, buildings, warehouses & facilities across the world. The risk and impact in the form of fire & explosion, burn, injury, shocks are high. Loss exposures also include financialas well as brand reputation. Many times, they cause interruptions in business continuity.

FIRE SAFETY AUDIT| Protech
Fire Safety Audit | A Risk-Based Independent Third Party Fire Safety Audit that takes care of the fire-related issues and hazards in a plant, warehouse, facility or building. Very specific subject matter experts (SME) with education, knowledge and experience in the field of fire & life safety and the relevant industry sector are used to conduct these audits.

Electrical Safety Management
Electrical safety hazards are increasingly posing higher risks to people and property in the form of shocks, burns, injury, fire and explosion. Electricity or electrical energy being a part and parcel of our everyday life; be it at our home or industry, it demand much higher awareness as well as effective management practices. With an increase in reported injuries and deaths associated with the use of electricity, this has become an area of concern for all types of industries.
Design Approach
COMPLETED

Occupancy - Assembly Built-up Area - 3251 sqm. Height - 15 Meter aprox.

Occupancy - Assembly Built-up Area - 45,99 acre Height - 31.55 Meter

Occupancy - Residential (Hostel) No of Blocks - 11 Height - 14.4 Meter

Occupancy - Residential (Hostel) Height - 30.99 Meter

Occupancy - Busines Area - 22 Acres Height - 90 Meters
ONGOING

Occupancy - Business (Office) Height - 20 Meter

Occupancy - Residential (Hotel) No of Rooms - 122 aprox. Height - 24.o5 meter

Occupancy - Residential (Hotel) No of Rooms - 74 aprox. Height - 52.27 Meters

Occupancy - Institutional (Hospital) No of Hospitals - 7 Units No of Beds - 765 Height - 40.6 Meters

Occupancy - Office Building Built-up Area - 27.58 acres. Height - 167.50 meter

Occupancy - Business (Office) Built-up Area - 36.99 acer Height - 51.10 Meter

Occupancy - Office Building Built-up Area - 47.69 Acre. Height - 63 meter

Occupancy - Office Built-up Area - 42.56 Acres. Height - 43.4 Meters

Occupancy - Residential Built-up Area - 16.15 Acres. Height - 150 meter